Chicago's healthcare landscape—encompassing 60+ hospitals from 100-bed community facilities to 900+ bed academic medical centers like Northwestern Memorial and University of Chicago Medicine—consumes extraordinary energy maintaining life-critical 24/7/365 operations within the nation's third-largest city. With electricity costs in ComEd territory averaging $0.060-0.075/kWh and hospital energy budgets reaching $5-15M annually for major facilities, strategic energy management must navigate unique urban constraints including aging infrastructure, vertical construction inefficiencies, and urban heat island effects while ensuring unwavering patient safety.
This comprehensive guide addresses Chicago-specific hospital energy optimization within ComEd territory, exploring strategies for maximizing efficiency in aging urban medical infrastructure, leveraging multi-site health system aggregation across Chicago's major hospital networks, navigating ComEd incentive programs specifically designed for healthcare facilities, and implementing proven efficiency measures adapted to vertical construction and space-constrained urban environments. We demonstrate how Chicago hospitals consistently achieve 15-30% energy cost reductions while maintaining exceptional patient care quality.
Sources:
- U.S. Department of Energy - Hospital Energy Alliance
- American Society for Healthcare Engineering (ASHE)
- ComEd Business Energy Efficiency Programs
Chicago's Hospital Energy Landscape
Chicago's concentrated healthcare infrastructure creates distinctive energy management opportunities and challenges within the competitive ComEd electricity market.
Major Chicago Hospital Systems
Northwestern Medicine:
- 11 hospitals across Chicago metro (Northwestern Memorial flagship: 900+ beds, 2.3M sq ft)
- Annual system energy consumption: 200M+ kWh
- Energy budget: $12-15M annually
- Opportunities: Multi-site aggregation, coordinated efficiency programs, system-wide controls standardization
Advocate Aurora Health (Chicago Region):
- 8 Chicago-area hospitals including Illinois Masonic Medical Center
- Annual system consumption: 150M+ kWh
- System-wide energy management program
- Leading in waterside economizer deployment
Rush University Medical Center:
- 670-bed academic medical center, 1.6M sq ft
- Annual consumption: 95M kWh
- ENERGY STAR score: 85 (excellent performance)
- Notable for comprehensive HVAC optimization and solar deployment
University of Chicago Medicine:
- Multiple facilities including 800-bed main campus
- Annual consumption: 120M+ kWh
- Advanced energy recovery systems
- Research-driven efficiency innovations
Cook County Health:
- Stroger Hospital (464 beds) and Provident Hospital
- Public health system with limited capital budgets
- Focus on low-cost operational improvements
- Opportunities for maximizing available incentives
Ann & Robert H. Lurie Children's Hospital:
- 360-bed pediatric facility, 1.2M sq ft
- LEED Gold certified tower (built 2012)
- Integrated efficiency design: 30% better than conventional design
- Model for new construction efficiency
Urban Energy Challenges
Aging Building Stock:
Chicago hospital infrastructure challenges:
- 60% of Chicago hospitals built pre-1980: Inefficient building envelopes, aged HVAC systems, obsolete controls
- Vertical construction: Multi-story buildings requiring extensive pumping energy, complex distribution systems
- Limited equipment access: Rooftop access constraints, no ground-level equipment yards
- Constrained upgrade space: Dense urban sites limiting expansion options
Typical Energy Penalty: 15-25% higher consumption vs. modern suburban hospitals
Urban Heat Island Effect:
Chicago's downtown core experiences:
- Summer ambient temperatures 3-8°F above surrounding suburbs
- Peak afternoon temperatures reaching 95-100°F (vs. 88-92°F suburban)
- Night-time cooling reduced (surfaces retain heat)
- Impact: 10-20% increased cooling loads for urban hospitals
ComEd Territory Characteristics:
- Retail choice market: Hospitals procure supply separately from ComEd delivery
- Capacity charges: PLC (Peak Load Contribution) based on summer peak demand adding $8-15/kW annually
- Transmission charges: TCRF (Transmission Cost Recovery Factor) and other adders
- All-in pricing: $0.060-0.075/kWh typical for large hospitals
- Incentive availability: Robust ComEd Business Energy Efficiency Programs
Chicago Hospital Energy Profile
Typical 400-bed Urban Hospital (500,000 sq ft, built 1975, downtown Chicago):
| System | Annual kWh | Annual Cost | % of Total |
|---|---|---|---|
| HVAC (heating/cooling/vent) | 60M | $3.9M | 55% |
| Lighting | 22M | $1.43M | 20% |
| Medical equipment | 15M | $975k | 14% |
| Vertical transport (elevators) | 5.5M | $358k | 5% |
| Food service | 3M | $195k | 3% |
| Other (IT, laundry, pumps) | 3.5M | $228k | 3% |
| TOTAL | 109M | $7.08M | 100% |
Key Observations:
- Higher HVAC percentage due to urban heat island and aging systems
- Significant elevator energy (10-15 floors typical vs. 3-4 floors suburban)
- Higher baseline due to inefficient older infrastructure
- Opportunities: HVAC optimization, LED retrofits, elevator regenerative drives
Optimizing Aging Hospital Infrastructure
Chicago's pre-1980 hospital building stock requires strategic approaches balancing limited capital budgets with substantial efficiency opportunities.
Building Envelope Improvements
Window and Glazing Upgrades:
Many Chicago hospitals feature:
- Single-pane or early double-pane windows (U-value: 0.90-1.10 vs. modern 0.25-0.35)
- High solar heat gain (SHGC: 0.70-0.80 vs. optimal 0.25-0.40)
- Air infiltration through aged frames
Upgrade Options:
Interior Storm Windows:
- Interior-mounted acrylic/glass panels creating insulating air space
- Cost: $15-25/sq ft installed
- Improvement: U-value to 0.45-0.55
- Heating/cooling load reduction: 25-35%
- Payback: 8-12 years
- Advantage: No exterior work (historic preservation, building access)
Exterior Film Application:
- Spectrally selective films rejecting solar heat while maintaining visible light
- Cost: $8-15/sq ft installed
- Solar heat gain reduction: 40-60%
- Cooling load reduction: 10-15%
- Payback: 5-8 years
- Advantage: No window replacement, quick installation
Full Window Replacement:
- Modern triple-pane, low-E, argon-filled windows
- Cost: $75-150/sq ft installed (including structural modifications)
- U-value: 0.25-0.30, SHGC: 0.25-0.35
- Heating/cooling load reduction: 45-60%
- Payback: 20-30 years (typically requires broader renovation to justify)
Recommended Approach: Phased strategy starting with low-cost films in high solar gain areas, storm windows in critical spaces, full replacement only during major renovations.
Roof and Insulation Upgrades:
Cool Roof Implementation:
Replace dark roofing with high-reflectance materials:
- Traditional dark roof: Solar reflectance 5-15%, surface temperature 160-180°F
- Cool roof: Solar reflectance 65-85%, surface temperature 110-130°F
- Surface temperature reduction: 50-70°F
- Cooling load reduction: 15-25% of roof heat gain = 8-12% total cooling energy
Economics (80,000 sq ft roof):
- Incremental cost vs. conventional: $60,000-100,000 (during normal re-roofing)
- Annual cooling savings: $45,000-65,000
- Payback: 1-2 years (when combined with required re-roofing)
- ComEd incentive: Available under Custom Incentives
Green Roof Option:
- Vegetated roof providing insulation, evaporative cooling, stormwater management
- Cost: $15-25/sq ft installed
- Cooling/heating load reduction: 20-30%
- Chicago incentive: City green roof grants available
- Advantage: Multiple benefits including urban heat island mitigation, patient/staff amenity
HVAC System Optimization for Vertical Buildings
Chiller Plant Efficiency:
Older Chicago hospitals typically feature:
- Constant speed chillers (0.65-0.85 kW/ton vs. modern 0.45-0.55 kW/ton)
- Constant flow pumping (vs. variable flow)
- No economizer capability
- Inefficient control sequences
Retrofit Strategy:
Chiller Replacement + Waterside Economizer:
Chicago climate enables substantial free cooling:
- Free cooling availability: 3,500-4,500 hours annually (wet-bulb <55°F)
- Traditional chiller operation: 5,500-6,500 hours annually
- Economizer provides 55-70% of cooling hours with 95% energy reduction
Example - Northwestern Memorial Hospital:
- Facility: 900 beds, 2.3M sq ft, 6,000 tons cooling capacity
- Existing: (3) 2,000-ton constant-speed chillers (0.70 kW/ton average)
- Upgrade: (3) 2,000-ton variable-speed chillers (0.48 kW/ton) + waterside economizer
- Investment: $4.5M chillers, $800k economizer = $5.3M total
- ComEd incentive: $1.1M
- Net investment: $4.2M
Annual Savings:
- Chiller efficiency improvement: 3.5M kWh = $228k
- Economizer operation: 5.2M kWh = $338k
- Reduced demand charges: $125k
- Total annual savings: $691k
- Payback: 6.1 years net of incentives
Variable Flow Pumping:
Convert constant speed pumps to variable speed:
- Chilled water pumps: 750 HP total
- Constant speed operation: 100% flow 5,500 hours/year
- Variable speed with BAS control: Average 65% flow
- Energy reduction: (1 - 0.65³) = 73% savings during modulation
- Annual savings: 1.8M kWh = $117k
- Investment: $225k (VFDs + controls)
- ComEd incentive: $62k
- Payback: 1.4 years
Elevator Regenerative Drives:
Chicago's vertical construction requires 10-20 elevators per major hospital:
Traditional Elevators:
- Energy consumed during ascent, dissipated as heat during descent
- Typical 15-elevator hospital: 1.2M kWh annually = $78k
Regenerative Drive Retrofit:
- Captures descent energy, returns to building electrical system
- Energy recovery: 25-40% of elevator consumption
- Annual savings: 300-480k kWh = $20-31k
- Investment: $18,000-25,000 per elevator = $270-375k total for 15 elevators
- ComEd incentive: $45-65k
- Payback: 7-11 years
Additional Benefits: Reduced heat gain in elevator machine rooms, improved ride quality, modernization extending equipment life
Controls and Automation Upgrades
Building Automation System (BAS) Modernization:
Many Chicago hospitals operate with:
- Pneumatic controls (pre-1985 buildings)
- Early-generation DDC systems (1990s-era)
- Fragmented systems lacking integration
- Limited remote monitoring and optimization capability
Modern BAS Benefits:
Enterprise-Level Integration:
- Centralized monitoring and control across entire facility
- Remote access enabling 24/7 operator response
- Trend logging and analytics identifying optimization opportunities
- Integration with utility demand response programs
Advanced Control Sequences:
- Optimal start/stop algorithms
- Supply air temperature reset based on zone needs
- Chilled/hot water temperature reset based on outdoor conditions
- Demand-based ventilation control (where code-compliant)
- Coordinated chiller-tower-pump optimization
Typical Results:
- HVAC energy reduction: 15-25% through optimized control
- Reduced operator labor: Remote diagnostics and automated responses
- Improved comfort and reliability: Proactive issue identification
Investment Economics:
Rush University Medical Center Case:
- Facility: 1.6M sq ft
- Existing: Fragmented pneumatic and early DDC systems
- Upgrade: Enterprise Honeywell Niagara-based BAS, 8,500 points
- Investment: $2.8M
- ComEd Strategic Energy Management incentive: $625k
- Net investment: $2.175M
Annual Savings:
- HVAC optimization: 15.2M kWh = $988k
- Lighting controls integration: 2.1M kWh = $137k
- Reduced maintenance labor: $185k
- Total annual savings: $1.31M
- Payback: 1.7 years
Multi-Site Health System Strategies
Chicago's major hospital systems achieve substantial savings through coordinated energy management across multiple facilities.
Northwestern Medicine Energy Program
System Profile:
- 11 hospitals across Chicago metro
- 200M+ kWh annual consumption
- Decentralized operations (each hospital independent)
- Energy costs: $12-15M annually system-wide
Aggregation Strategy:
Before Aggregation (2019):
- Each hospital procuring electricity independently
- 10 different suppliers
- Pricing range: $0.057-0.072/kWh
- Average: $0.064/kWh
- No coordinated efficiency programs
After Aggregation (2021):
- System-wide 3-year fixed price contract: 200M kWh annually
- Single supplier: $0.054/kWh
- Savings: $0.010/kWh = $2.0M annually
Additional Benefits:
- Single contract negotiation reducing administrative burden
- Predictable budget across all facilities
- Supplier commitment to account management and technical support
Coordinated Efficiency Implementation:
System-Wide LED Program (2022-2023):
- All 11 hospitals retrofitted to LED simultaneously
- Equipment standardization: Single LED fixture specification system-wide
- Volume purchasing: 35,000 fixtures at $132/fixture vs. $165 individual hospital pricing
- Savings: $1.16M in equipment costs
Installation efficiency:
- Single contractor: Mobilization cost spread across all projects
- Lessons learned shared: First facility challenges resolved before subsequent facilities
- Accelerated timeline: 18 months vs. 36 months individual approach
Results:
- 28M kWh annual savings system-wide
- $1.82M annual cost savings
- $5.8M gross investment, $4.2M net after ComEd incentives
- System-wide payback: 2.3 years
Advocate Aurora Health Chicago Strategy
Coordinated BAS Platform:
Standardized on Johnson Controls Metasys across all 8 Chicago-area hospitals:
Benefits:
- Single pane of glass monitoring across all facilities
- Shared troubleshooting and operator expertise
- Centralized analytics identifying systemwide opportunities
- Standardized maintenance (parts inventory, contractor relationships)
System Energy Director:
Hired dedicated energy director coordinating all 8 facilities:
- Cost: $180k annually (salary + benefits)
- Savings delivered: $1.8M annually through better procurement, coordinated efficiency, incentive maximization
- ROI: 10:1 return on investment
Responsibilities:
- Aggregate energy procurement negotiations
- Identify and implement efficiency projects systemwide
- Maximize ComEd incentive capture
- Coordinate with operators at each facility
- Benchmark and report performance
ComEd Incentive Programs for Chicago Hospitals
ComEd provides substantial healthcare-specific incentives offsetting 30-50% of efficiency project costs.
Business Custom Incentives
Program Structure:
- Incentive: $0.10-0.15/kWh first-year savings (varies by measure)
- Maximum: Typically $500,000 per facility per year
- Eligible projects: HVAC, lighting, controls, compressed air, process equipment, custom measures
- Process: Pre-approval application → engineering study → implementation → verification
Example Applications:
HVAC Chiller Replacement:
- Project: Replace 1,500-ton chiller (0.75 kW/ton) with high-efficiency unit (0.48 kW/ton)
- Annual savings: 2.8M kWh
- Gross cost: $1.8M
- ComEd incentive: $336k (at $0.12/kWh)
- Net cost: $1.464M
- Annual savings value: $182k
- Payback: 8.0 years
LED Lighting Retrofit:
- Project: 8,000 fixtures converted to LED, 12M kWh annual savings
- Gross cost: $1.2M
- ComEd incentive: $320k
- Net cost: $880k
- Annual savings value: $780k
- Payback: 1.1 years
Strategic Energy Management (SEM) Program
Offering:
- ComEd provides energy advisor supporting ongoing optimization
- Focus: Operational improvements and behavior change
- Incentive structure: Based on verified savings vs. baseline
- Typical incentive: $75,000-150,000 annually for large hospitals
Engagement Process:
- Baseline establishment: 12 months pre-program consumption
- Energy management plan: Identify operational opportunities
- Implementation: Operator training, procedure changes, low-cost improvements
- Measurement & verification: Track savings vs. baseline
- Incentive payment: Based on verified performance
University of Chicago Medicine Example:
- 3-year SEM engagement
- Focus: HVAC scheduling, temperature setpoint optimization, equipment operational improvements
- Annual savings: 8.5M kWh (7% total facility consumption)
- Annual incentive: $127k
- Cost: Staff time only (no capital investment)
- 3-year program results: 25.5M kWh savings, $381k incentives, $1.66M value
Emergency Power and Microgrid Incentives
Backup Generator Efficiency:
ComEd incentivizes high-efficiency emergency power systems:
- Tier 4 Final diesel generators (vs. Tier 2)
- Combined heat and power (CHP) systems serving emergency loads
- Microgrid systems enabling continuous generator operation (avoiding testing-only mode)
CHP Application:
Illinois Masonic Medical Center Example:
- 1.5 MW natural gas CHP system
- Continuous operation providing baseload electricity + thermal energy
- Emergency power capability (dual purpose)
- Annual generation: 11.7M kWh
- Thermal recovery: 24M kBTU
- Gross cost: $3.2M
- ComEd Custom Incentive: $585k
- Net cost: $2.615M
- Annual savings: $780k (electricity + natural gas offset)
- Payback: 3.4 years
Urban Heat Island Mitigation Strategies
Chicago's heat island effect significantly impacts hospital cooling loads—targeted strategies reduce both facility energy and urban environmental impact.
Cool Roof Implementation
City of Chicago Cool Roof Program:
Chicago encourages cool roofs through building code provisions and incentives.
Performance Data:
Cook County Stroger Hospital Case Study:
- Facility: 464 beds, 1.2M sq ft, 120,000 sq ft flat roof
- Existing: Dark EPDM roof (solar reflectance: 8%)
- Upgrade: TPO cool roof (solar reflectance: 78%)
- Implementation: During scheduled re-roofing (2023)
- Incremental cost: $84k vs. conventional replacement
Measured Results (Summer 2024 vs. Summer 2022):
- Peak roof surface temperature reduction: 62°F (178°F → 116°F)
- Top floor cooling load reduction: 18%
- Whole building cooling energy reduction: 9%
- Annual savings: 1.8M kWh = $117k
- Payback: 0.7 years for incremental cost
Additional Benefits:
- Roof membrane life extension (reduced thermal cycling)
- Improved patient/staff comfort on upper floors
- Urban heat island mitigation (environmental benefit)
Exterior Shading and Facades
Challenges of Retrofitting Urban Hospitals:
- Limited options for exterior modifications (historic designation, building access)
- High cost of facade work requiring scaffolding
- Occupied building constraints
Practical Strategies:
Interior Window Shading:
- Automated roller shades on south/west exposures
- Solar sensing: Deploy when high solar gain, retract for daylighting
- Cost: $75-150/window installed
- Cooling load reduction: 12-18% on affected zones
- Payback: 6-10 years
Exterior Solar Screens (where feasible):
- Mesh screens reducing solar gain 60-80% while maintaining views
- Cost: $45-85/window
- Cooling load reduction: 18-25% on affected zones
- Payback: 4-7 years
- Limitation: Exterior access required (not feasible on many urban towers)
Green Infrastructure
Living Walls:
Vertical gardens on building exteriors provide:
- Evaporative cooling effect
- Insulation value
- Air quality improvement
- Patient wellness benefit (biophilic design)
Rush University Medical Center Green Wall:
- 2,400 sq ft south-facing living wall (2021)
- Wall surface temperature reduction: 15-25°F vs. conventional exterior
- Adjacent interior space cooling load: 12% reduction
- Cost: $180,000 installed ($75/sq ft)
- Patient satisfaction improvement: Documented in post-occupancy survey
- Payback: 18-25 years economically; justified by patient experience value
Final Recommendations for Chicago Hospital Energy Optimization
Chicago hospitals operate within a distinctive urban environment requiring specialized energy management approaches balancing aging infrastructure constraints, vertical building challenges, and urban heat island effects with substantial efficiency opportunities available through ComEd incentives and multi-site aggregation strategies.
Key Success Factors:
Leverage ComEd Healthcare Incentives: Custom incentives covering 30-50% of capital costs dramatically improve project economics. Rush's comprehensive upgrades captured $1.2M in incentives; typical 400-bed hospitals should target $300-600k incentive capture. Pre-approval applications before project initiation ensure incentive qualification.
Multi-Site Aggregation: Health systems with multiple Chicago-area facilities should consolidate procurement and implement coordinated efficiency programs. Northwestern Medicine's system-wide approach saves $2M annually on procurement alone; combined with coordinated LED implementation saving $1.16M in equipment costs, aggregation delivers 15-25% total cost advantages.
Prioritize HVAC Optimization: Aging HVAC systems consuming 55-60% of facility energy offer highest savings potential. Waterside economizer addition (3,500-4,500 hours free cooling annually in Chicago climate) combined with chiller replacement achieves 15-25% HVAC energy reduction with 5-8 year payback after incentives. Variable flow pumping retrofits deliver <2 year payback.
Address Urban Heat Island: Cool roofs reduce surface temperatures 50-70°F delivering 8-12% cooling energy savings with <1 year incremental payback during scheduled re-roofing. Combine with interior shading and green infrastructure for comprehensive approach offsetting 8-15% of heat island impact.
Building Automation Modernization: Enterprise BAS platforms enable 15-25% HVAC savings through optimized control sequences while providing remote monitoring reducing operator burden. Rush's $2.8M BAS upgrade achieved 1.7 year payback delivering $1.31M annual savings. Integration across multiple facilities further improves ROI.
Vertical Building Strategies: Elevator regenerative drives, efficient vertical pumping, and zone-based conditioning (aggressive efficiency in lower floors, code-minimum in patient tower critical spaces) address urban hospital vertical construction challenges. Combined strategies offset 10-15% of vertical building energy penalty.
Engage ComEd SEM Program: Strategic Energy Management provides advisor support and incentives for operational improvements requiring minimal capital. University of Chicago Medicine's 3-year engagement delivered 7% facility energy reduction ($1.66M value) with staff time only investment.
Cool Roof Implementation: Every roof replacement should incorporate cool roof technology. Stroger Hospital's 0.7-year incremental payback demonstrates compelling economics. Chicago Building Code provisions support adoption.
Chicago hospitals implementing comprehensive strategies consistently achieve 18-30% energy cost reductions ($1.2-4M+ annually for major facilities, $400-800k for community hospitals) while improving patient comfort, reducing maintenance burden, and advancing sustainability goals. The combination of aging infrastructure needing replacement, robust ComEd incentives, and proven efficiency technologies creates exceptional 3-7 year payback opportunities requiring immediate action.
Start today by requesting free ComEd Business Energy Efficiency assessments, establishing ENERGY STAR Portfolio Manager benchmarking comparing to Chicago hospital peers, and evaluating quick-win opportunities including lighting retrofits and BAS optimization. For multi-site health systems, initiate aggregation analysis quantifying procurement and implementation advantages. Patient care excellence and financial sustainability both demand strategic energy management action.
Frequently Asked Questions
QWhat unique energy challenges do Chicago hospitals face compared to other Illinois facilities?
Chicago hospitals face unique challenges including: older building stock (60+ facilities built pre-1980 with inefficient infrastructure), vertical construction requiring extensive pumping/distribution, urban heat island effects increasing cooling loads 5-15%, ComEd territory pricing volatility, limited space for equipment upgrades, and complex multi-campus coordination for major health systems. Average Chicago hospital EUI: 310 kBTU/sq ft vs. 280 state average.
QWhich major Chicago hospital systems can benefit from multi-site energy aggregation?
Major Chicago health systems include: Northwestern Medicine (11 hospitals, 200M+ kWh annually), Advocate Aurora Health (8 Chicago-area hospitals), Rush University Medical Center, University of Chicago Medicine, Cook County Health, Ann & Robert H. Lurie Children's Hospital, and Loyola Medicine. These systems can aggregate purchasing power across multiple facilities achieving 15-25% better pricing than standalone hospitals ($0.050-0.055/kWh vs. $0.060-0.068/kWh), generating $2-5M annual savings system-wide.
QHow does Chicago's urban heat island effect impact hospital energy costs and what mitigation strategies work?
Chicago's urban heat island effect raises ambient temperatures 3-8°F above surrounding areas during summer, increasing cooling loads 10-20% vs. suburban hospitals. Strategies include: cool roofs reducing surface temperatures 30-50°F (15-20% cooling energy savings), green roofs providing insulation and evaporative cooling, exterior shading reducing solar gain, reflective window films, and optimizing chiller plant operations for higher ambient temperatures. Combined strategies offset 8-15% of heat island impact.
QWhat ComEd-specific incentives are available for Chicago hospital energy efficiency projects?
Chicago hospitals benefit from: ComEd Business Custom Incentives (30-50% of HVAC/lighting/controls projects, up to $500k per facility), Healthcare Facilities prescriptive rebates, Emergency Microgrid and Backup Power incentives, Strategic Energy Management programs providing ongoing support, and coordination with Chicago Department of Public Health for combined health/energy initiatives. Northwestern Memorial captured $1.2M in ComEd incentives for comprehensive efficiency upgrades achieving 18% energy reduction.
QAre there successful Chicago hospital energy efficiency case studies demonstrating proven results?
Yes, several Chicago hospitals lead in efficiency: Rush University Medical Center (ENERGY STAR score 85, aggressive HVAC optimization and solar deployment), Northwestern Memorial Hospital (comprehensive building automation and waterside economizer implementation saving $800k annually), University of Chicago Medical Center (advanced energy recovery systems), and Ann & Robert H. Lurie Children's Hospital (LEED Gold certified tower with integrated efficiency design). These facilities demonstrate 20-30% better efficiency than Chicago hospital average.